Mine Cable
Black Elephant / Customizable
Availability: | |
---|---|
Quantity: | |
Application: Mine Cable is a heavy-duty trailing cable where flexibility and maximum protection is required. For use with mobile, reeling, or stationary mining equipment, continuous mining machines, longwall mining systems, and blast hole drillers,ect.
Suitable for mobile laying cable used in mining power plant with rated power-frequency voltage U0/U 8.7/10kV and below
Standard: UL 1650/ICEA S-75-381
At the same time, we can also produce according to the IEC, British, German and American standards recommended by the International Electrotechnical Commission.
Construction:
1. Conductor: Plain or Tin coated, soft drawn, annealed, flexible, rope-lay stranded copper per ASTM B-33/B-172.
2. Conductor shield: extruded semi-conductive layer.
3. Insulation: Black Ethylene Propylene Rubber (EPR)
4. Insulation shied: Extruded semi-conductive layer.
5. Wrapping tape
6. Braid shield: Tin coated, soft drawn, annealed, copper braid shield (60% min. phase coverage), duplexes with nylon textile buffer colour code tracer (40% max. phase coverage).
7. Grounding Conductors: Two coated copper, rope-lay-stranded per ASTM B172
8. Ground-Check-Conductor: Annealed tinned copper, rope-lay-stranded per ASTMB172, insulated.
9. Binder tape
10. Reinforcement.
11. Extra heavy-duty, CPE.
Specifications:
Size (AWG) | Insulation inch mm | Grouding conductor Size Min.strandes | Groud check Size Ins. inch | |||
6 | 0.070 | 1.78 | 10 | 19 | 10 | 0.76 |
4 | 0.070 | 1.78 | 8 | 49 | 10 | 0.76 |
3 | 0.070 | 1.78 | 7 | 49 | 10 | 0.76 |
2 | 0.070 | 1.78 | 6 | 49 | 10 | 0.76 |
1 | 0.080 | 2.03 | 5 | 133 | 8 | 1.14 |
1/0 | 0.080 | 2.03 | 4 | 133 | 8 | 1.14 |
2/0 | 0.080 | 2.03 | 3 | 133 | 8 | 1.14 |
4/0 | 0.080 | 2.03 | 1 | 133 | 8 | 1. |
Edit broadcasts using features:
● Rated power frequency voltage U0/U is 380/660V, 660/1140V, 1.9/3.3kV, 3.6/6kV, 6/10kV, 8.7/10kV, 300/500V.
Max. admissible operating temperature of conductor: 65℃ 90℃
● The cable allows the lowest operating ambient temperature of -35℃
● Bending radius of cable: not more than 6 times of cable diameter.
Mining cables include : MC cable, MCP cable, MZ cable, MZP cable, MYQ cable, MY cable, MCPTJ cable, MYPTJ cable, MVV cable, MKVV cable, MYJV cable, MKYJV cable, MHYV cable, UGF cable, high voltage mining cable, 10kV rubber sleeve cable, 6kV mining cable, Mining mobile cable, mining flame retardant cable, MCPT cable, mining rubber sheathed cable.
Application: Mine Cable is a heavy-duty trailing cable where flexibility and maximum protection is required. For use with mobile, reeling, or stationary mining equipment, continuous mining machines, longwall mining systems, and blast hole drillers,ect.
Suitable for mobile laying cable used in mining power plant with rated power-frequency voltage U0/U 8.7/10kV and below
Standard: UL 1650/ICEA S-75-381
At the same time, we can also produce according to the IEC, British, German and American standards recommended by the International Electrotechnical Commission.
Construction:
1. Conductor: Plain or Tin coated, soft drawn, annealed, flexible, rope-lay stranded copper per ASTM B-33/B-172.
2. Conductor shield: extruded semi-conductive layer.
3. Insulation: Black Ethylene Propylene Rubber (EPR)
4. Insulation shied: Extruded semi-conductive layer.
5. Wrapping tape
6. Braid shield: Tin coated, soft drawn, annealed, copper braid shield (60% min. phase coverage), duplexes with nylon textile buffer colour code tracer (40% max. phase coverage).
7. Grounding Conductors: Two coated copper, rope-lay-stranded per ASTM B172
8. Ground-Check-Conductor: Annealed tinned copper, rope-lay-stranded per ASTMB172, insulated.
9. Binder tape
10. Reinforcement.
11. Extra heavy-duty, CPE.
Specifications:
Size (AWG) | Insulation inch mm | Grouding conductor Size Min.strandes | Groud check Size Ins. inch | |||
6 | 0.070 | 1.78 | 10 | 19 | 10 | 0.76 |
4 | 0.070 | 1.78 | 8 | 49 | 10 | 0.76 |
3 | 0.070 | 1.78 | 7 | 49 | 10 | 0.76 |
2 | 0.070 | 1.78 | 6 | 49 | 10 | 0.76 |
1 | 0.080 | 2.03 | 5 | 133 | 8 | 1.14 |
1/0 | 0.080 | 2.03 | 4 | 133 | 8 | 1.14 |
2/0 | 0.080 | 2.03 | 3 | 133 | 8 | 1.14 |
4/0 | 0.080 | 2.03 | 1 | 133 | 8 | 1. |
Edit broadcasts using features:
● Rated power frequency voltage U0/U is 380/660V, 660/1140V, 1.9/3.3kV, 3.6/6kV, 6/10kV, 8.7/10kV, 300/500V.
Max. admissible operating temperature of conductor: 65℃ 90℃
● The cable allows the lowest operating ambient temperature of -35℃
● Bending radius of cable: not more than 6 times of cable diameter.
Mining cables include : MC cable, MCP cable, MZ cable, MZP cable, MYQ cable, MY cable, MCPTJ cable, MYPTJ cable, MVV cable, MKVV cable, MYJV cable, MKYJV cable, MHYV cable, UGF cable, high voltage mining cable, 10kV rubber sleeve cable, 6kV mining cable, Mining mobile cable, mining flame retardant cable, MCPT cable, mining rubber sheathed cable.