VDE JZ 600
Black Elephant / Customizable
Availability: | |
---|---|
Quantity: | |
Used as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, in plant construction, heating and air-conditioning technology, in smelters and steel mills.
Suitable for flexible applications involving medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation).
May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 18.0 mm) or water. Primarily used in southern European and Arabic countries, as well as in eastern states.
Structure
Bare copper conductor:
DIN VDE O295 Class 5, fine copper wire, BS 6360 Class 5, IEC60228 Class 5 special PVC TI2
Core wire insulation :
in accordance with DIN VDE 0207-363-3/DIN EN 50363-3
The marking of wire core:
complies with DIN VDE 0293. Black wire core, continuous white number yellow and green ground wire The outer wire (3 or more core wires) is made of special PVC TM2 outer sheath with pitch layered-stranded. In accordance with DINVde 0207-363-4-1/DINEN 50363-4-1 black outer sheath (RAL 9005) with meter mark
Technical parameters
- Test voltage 3000 V conforms to DIN VDE 0281, Part 2 HD 21.2
- Small bending radius: 7,5 x d
- Radiation resistance: 8 x 10 7 cJ/kg
- Temperature range: Fixed laid: -40/70 °C; Mobile installation: 5/70 °C
- Flame retardant characteristics: flame retardant and self-extinguishing
- Comply with IEC 60332-1-2 EN 60332-1-2
- Oil resistance: meets internal standards
- Flexibility: Good
- Oil resistance: Very good TMPU conforms to DIN VDE 0282 Part 10 HD 22.10
- Chemical resistance: good resistance to acid, alkali, solvent, hydraulic oil and other properties
- Special PVC control cables conform to DIN VDE O262 and DIN VDE 0285-525-2-5 / DIN EN 50525-2-51, with insulation, wall thickness suitable for 1kV
- Temperature range -15℃C to +80℃ for mobile installation -40℃C to +80℃ for fixed installation
- Nominal voltage Uo/U 0.6/1 kV Test voltage 4000 V breakdown voltage 8000 V low
- Insulation resistance 20 MOhm x km
- Bending radius 7.5x cable diameter 7.5x cable diameter fixed 4x cable diameter
- Radiation resistance 80x10 cJ/kg (80 Mrad)
Item | JZ-600 Control Cable |
Conductor | Copper wire bare |
Insulation | PVC/XLPE |
Sheath | PVC |
Nominal voltage | AC U o /U 600/1000 V |
Test voltage core/core | 4000V |
Breakdown voltage | 8000 V |
Temperature Range | Flexible -15°C to +80°C Fixed -40°C to +80°C |
Color | Optional |
Certification | CE ISO TUV VDE |
Used as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, in plant construction, heating and air-conditioning technology, in smelters and steel mills.
Suitable for flexible applications involving medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation).
May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 18.0 mm) or water. Primarily used in southern European and Arabic countries, as well as in eastern states.
Structure
Bare copper conductor:
DIN VDE O295 Class 5, fine copper wire, BS 6360 Class 5, IEC60228 Class 5 special PVC TI2
Core wire insulation :
in accordance with DIN VDE 0207-363-3/DIN EN 50363-3
The marking of wire core:
complies with DIN VDE 0293. Black wire core, continuous white number yellow and green ground wire The outer wire (3 or more core wires) is made of special PVC TM2 outer sheath with pitch layered-stranded. In accordance with DINVde 0207-363-4-1/DINEN 50363-4-1 black outer sheath (RAL 9005) with meter mark
Technical parameters
- Test voltage 3000 V conforms to DIN VDE 0281, Part 2 HD 21.2
- Small bending radius: 7,5 x d
- Radiation resistance: 8 x 10 7 cJ/kg
- Temperature range: Fixed laid: -40/70 °C; Mobile installation: 5/70 °C
- Flame retardant characteristics: flame retardant and self-extinguishing
- Comply with IEC 60332-1-2 EN 60332-1-2
- Oil resistance: meets internal standards
- Flexibility: Good
- Oil resistance: Very good TMPU conforms to DIN VDE 0282 Part 10 HD 22.10
- Chemical resistance: good resistance to acid, alkali, solvent, hydraulic oil and other properties
- Special PVC control cables conform to DIN VDE O262 and DIN VDE 0285-525-2-5 / DIN EN 50525-2-51, with insulation, wall thickness suitable for 1kV
- Temperature range -15℃C to +80℃ for mobile installation -40℃C to +80℃ for fixed installation
- Nominal voltage Uo/U 0.6/1 kV Test voltage 4000 V breakdown voltage 8000 V low
- Insulation resistance 20 MOhm x km
- Bending radius 7.5x cable diameter 7.5x cable diameter fixed 4x cable diameter
- Radiation resistance 80x10 cJ/kg (80 Mrad)
Item | JZ-600 Control Cable |
Conductor | Copper wire bare |
Insulation | PVC/XLPE |
Sheath | PVC |
Nominal voltage | AC U o /U 600/1000 V |
Test voltage core/core | 4000V |
Breakdown voltage | 8000 V |
Temperature Range | Flexible -15°C to +80°C Fixed -40°C to +80°C |
Color | Optional |
Certification | CE ISO TUV VDE |